AETEC ENGINEERING← Back to simulator
ASM / IN-HOUSE TECHNICAL REFERENCE

Engineering notes.

Source dimensions, metrology and control demonstrations supporting the interactive simulator.

01 / SOURCE AND SCOPE

What was checked.

Archived nominal paths

The original sampled geometric checks reported no unintended contact in 26,481 mobile, 31,873 fixed-POC and 6,565 carrier configurations. These are discrete geometric checks; they do not establish continuous clearance, force limits, quartz stress or machine safety.

The full mission joins the carrier handover to the matching supported installation pose. Its playback uses the original review samples; it does not generate new robot commands or apply measured offsets.

Assembly and geometry

UR30 visuals use the Universal Robots description meshes. The MiR250 is a community reference model. The chamber and machine use annotated customer dimensions and identified estimates. Pin/hole diameters, coupler approval, payload, stability and ISO 7 qualification are open items.

Two temporary guides are optional. Their install/remove sequence is a planning study; no corresponding robot path or collision result was recovered.

02 / CUSTOMER SOURCE

The machine, its datums and its guides

All ten slides were reviewed. Slides 7 and 8 also contain three embedded STEP files: the existing tong and left/right installation guides. The machine outline is reconstructed; only annotated dimensions are source dimensions.

Reconstructed customer machine with nominal frame dimensions
Upper cabinet, open frame, side platens, front tube notch, well and exhaust funnel. Unlabelled frame sizes remain estimates.
Automatic exchange from installation trolley A to inspection trolley B
Trolley A returns to its bay. The same MiR250 + UR30 captures trolley B and returns for optional inspection.
Front layout with container left and robot in front
Front access leaves the approach corridor open.
Top view of the checked layout
The side container, stabilizer feet and enclosure remain in the collision model.
FeatureModel valueEvidence
Type 1 quartz759 × 490 × 159 mm fin envelopeCustomer slide 5
Type 1 body113 mm external height; 88 / 433 mm internal openingCustomer callouts; remaining wall dimensions inferred
TubulationØ34; 355 mm upper datum to tipTube tip −219 mm relative to fin bottom in this reconstruction; 378 mm total height
Machine access850 / 550 / 1250 mm850 window; 550 transverse interpretation and 1250 seat datum require confirmation
Pin / guide spacing700 / 310 / 450 / 230 mmSource annotated views; pin Ø8 and hole Ø10 are explicit assumptions
Machine frame envelope830 × 1130 × 2743 mm nominalApproximate image-proportion reconstruction, not a toleranced machine drawing
Installation guides400 mm CAD lengthCustomer guide reference retained; robot-handled sleeves and mounts are proposed geometry
Floor10 kN/m²Distributed rating; concentrated foot loads require separate approval

03 / METROLOGY AND HANDLING

Camera first. Probe second.
Verify the part after pickup.

T1 measures before exchange. The upward camera and probe stay fixed on trolley A while the robot presents the held chamber to them. A rigid pose correction cannot repair a mismatched hole pattern.

Separate T1 camera and probe, T2 load sensing carrier, and T3 guide gripper
T1 camera + touch probe. T2 fin-gap carrier with independent load and force/torque sensing. Optional T3 handles two guiding fixtures; T4 adds camera/probe/laser inspection on trolley B. Optional T5 grasps an approved rigid lid handle; it is not a fourth trolley.
Upward camera and independent probe checking the retained quartz
Three datum holes and the bottom plane are checked after pickup. The tubulation remains in an open clearance region.
ConditionControl response
Chamber stuck in foamExcess extraction force, load imbalance or abnormal moment → retained HOLD. No harder pull.
Vision / probe disagreementHold; inspect identification, datums and calibration. Measurement diversity does not automatically establish safety redundancy.
Final pin engagementSquare approach; slow vertical seating with independent force/torque monitoring. No forced search.
ReleaseConfirm all three seats and load handover; unload pads before opening.

Offline three-hole / three-pin registration

Enter three identified, calibrated centres in mm, in the order front, rear-left, rear-right. This synthetic example assumes a 35 mm pin-tip-to-seat offset and a 0.2 mm pattern check limit. These values are illustrative, not accepted process tolerances.

This is a separate offline calculator. Its result never changes the recorded robot path.

CONTROL ARCHITECTURE / REV G

Requests become confirmed machine states

The operator interface shows the active step, the blocking condition and the evidence needed to continue. The cell controller owns the sequence and verifies each device response.

Control architecture: HMI and metrology connect to cell PLC, UR controller, MiR adapter and sensor I/O; safety channels are independent
Proposed connections. PLC selection, protocols, safety performance and machine handshakes are finalized during detailed design.

HMI and industrial PC

Select a job, machine, box and recipe. See requested and confirmed tools, calibration, fit quality, support condition and alarms. Requests go through the cell PLC.

Cell PLC and device links

The sequencer checks permissives, timeouts, latches and ownership. UR executes approved paths; RTDE supplies trace data. A supervised MiR REST adapter handles normal missions and arrival status.

Independent safety path

Risk-assessed protective stops and motion inhibits use separate validated channels. The HMI mirrors their state. Camera/probe agreement and ordinary network data are not automatically safety-rated.

Records and recovery

Link job, tool, trolley and calibration IDs to images, raw touches, transforms and sensor traces. Detect gaps or failed storage. Preserve the fault window; acknowledgement does not restart motion.

Gate-by-gate flows for mobile installation, fixed POC and optional container carrier
Arrival → support → registration → tool exchange → pickup and check → seating and record. A missing gate causes a retained HOLD.

INTERACTIVE SUPPORT DEMO

Unequal loads can still be stable

This four-contact illustration assumes all vertical load is measured at known coplanar feet. Actual loaded wheels, stopping forces and structure must be included in the final model.

Illustrative reaction centre

The 80 mm operating margin shown here is an example, not a released threshold. Do not re-level while holding quartz.

CONFIRMED TOOL DEMO

Changing the request does not change the actual tool

Requested
NONE
Actual
NONE
Lock / services
OPEN

Assumes an empty tool and a supported nest. No real equipment connection.

  1. Request the selected tool
  2. Return current tool to its supported nest
  3. Confirm release, then capture the next tool
  4. Verify ID, lock, services and tool model
  5. Publish confirmed actual tool and enable its recipe
Optional T5 gripper opening a retained rigid lid
Manual opening is standard. T5 is optional: positive rigid-handle grasp, retained-open check and camera verification before quartz handling. Porous foam is not a suction surface.
Eight-box storage example with one selected box
Carrier C selects one labelled Q02 box. It withdraws to a clear aisle before turning, transports and docks, then transfers weight to monitored floor stands.

OPERATOR INTERFACE / DIAGNOSTICS

Every handover has a record

Independent interactive software design demonstration. Synthetic signals only; no robot or safety-controller connection. A production historian needs separate implementation and validation.

JOB CONTROL / LOCAL DEMOIDLE

Opening browser-local journal…

LIVE SEQUENCE / SIMULATED

Reserve machine

  1. Job / reservation
  2. Trolley identity
  3. Dock / lock
  4. Tool / calibration
  5. Camera first
  6. Three locating pins
  7. Three seating contacts
  8. Automatic tool change
  9. Force-monitored pickup
  10. Fixed upward metrology
  11. Level approach / seat
  12. Unload / complete
Pin fit 0.03 mm · exampleProbe / camera Cross-check requiredSupport 4 loads + displacementRetention Mechanical / power-off

FAULT WINDOW / 10 S BEFORE + 20 S AFTER

Keep the evidence around a fault

Reset only acknowledges. It never restarts the job. The buffer continues collecting post-fault samples while motion is held.

Event journal

Job, machine, trolley, tool, calibration, timestamps, image references and raw probe points are traceable.

SequenceUTC timeEventTrolley

The demo stores events in this browser and keeps a bounded 10-second synthetic trace ring. Production design: local append-only journal, durable fault files, synchronized clocks, retention policy and a HOLD on mandatory logging failure.

Paired rigid coupling concept
Spaced capture keys and mechanical retention. AprilTag/RFID identity is separate from final mechanical seating.
Quartz box carrier on floor stands
Optional C transports the box, then leaves it on stable floor supports with wheels unloaded.
REFERENCE RECORDINGS / REV H

Narrated reference films.

Separate from the interactive 3D simulator. The recordings load only when requested.

Mobile system · complete sequence

Fixed robot · proof of concept